DEM AudioLinFIR Documentation
LinFIR

IR Management


On this page

The IR (Impulse Response) Management window provides comprehensive tools for obtaining, processing, and managing impulse responses for each driver or measurement position in your system.

IR Management Window IR Management Window

Accessing IR Management

Loudspeaker Design Mode:

  • To open: Driver → Manage IR
  • Purpose: Import, capture, and process driver impulse responses at multiple angles

Room Calibration Mode:

  • To open: Measurements → Manage IR
  • Purpose: Capture IR at a given in room position

Window Layout

The window has two modes, switched by the Polar toggle at the right of its title (Loudspeaker Design mode):

  • Off (the default for a driver without off-axis measurements): the window is about the on-axis measurement — its capture or import, its windowing and calibration. The angle controls and the measurement list are hidden; a driver that has off-axis measurements says how many, with a Polar mode button.
  • On: the window widens. On the left, the same sections plus the axis / angle selectors, the ▶ Scan button and the Measurements list; on the right, the Enclosure card above the drawings of the setup for both planes (see The Enclosure and the Rotation Center). Folding the card gives the drawings its room; the drawings grow when the window is enlarged. It opens in this mode for a driver that has off-axis measurements.

The top of the window holds the controls you use on every capture — the name field, the axis / angle selectors (polar mode), and the 📁 Import, 🎤 Measure and ▶ Scan buttons.

Everything below is organized into collapsible sections, in this order:

  1. Measurement Settings — sweep parameters (duration, level, start / end frequency, …). Open by default. These configure the capture buttons above, not the list below. See Sweep Measurements.
  2. Measurements — the captured / imported angles, in two columns (horizontal, vertical), with per-measurement actions. Polar mode only.
  3. Near-field measurements (splicing) 🔒 — element status and the Open splicing wizard… button. Collapsed by default. Not shown in Room Calibration mode. See below.
  4. Measurement Calibration — per-driver microphone and soundcard calibration selection, and the SPL calibration that shows the measurements in dB SPL. Collapsed by default; shown before any measurement too, since the chain is best calibrated first.
  5. IR Windowing — time window, adaptive window, delay compensation.
  6. Measurement Notes — free-text notes saved with the project. Collapsed by default.
  7. IR Information — read-out of the current measurement's properties.

Driver/Measurement Name

Manually enter a descriptive name for the impulse response.

  • Label: "Driver Name" (Loudspeaker Design) or "Measurement Name" (Room Calibration)
  • Purpose: Identify IRs in project and exports
  • Persistence: Names are saved with the project
  • Optional: Empty names default to "Driver X" or "Measurement X"
  • Best practice: Use descriptive names like "Woofer_Left", "Tweeter_RefXYZ", "Position_Center"

Capturing IR

Button: 🎤 Measure

Triggers a measurement sweep with the configured parameters to capture the impulse response.

Features:

  • Exponential sine sweep generation with configurable parameters
  • Automatic harmonic distortion analysis (THD)
  • Timing reference support for multi-driver measurements

For complete documentation on sweep parameters, driver protection, measurement workflow, and best practices, see Sweep Measurements.


Off-Axis Measurements 🔒

Available in: Loudspeaker Design mode, in the window's polar mode License required: Valid LinFIR license needed for off-axis measurements

Overview

Off-axis measurements enable directivity analysis by capturing impulse responses at different horizontal and vertical angles. These measurements are essential for understanding speaker radiation patterns and optimizing crossover design for consistent off-axis response.

Measurement Organization

Measurements are displayed in two columns:

  • Horizontal column: Measurements with vertical angle = 0°, varying horizontal angle

    • Example: -90°, -60°, -30°, 0°, +30°, +60°, +90°
  • Vertical column: Measurements with horizontal angle = 0°, varying vertical angle

    • Example: -60°, -40°, -20°, 0°, +20°, +40°, +60°

On-axis reference: The (0°, 0°) measurement appears in both columns.

Axis Selection

Before importing or capturing an off-axis measurement, select the measurement axis:

  • Horizontal button: Measurements along horizontal axis (left/right)
  • Vertical button: Measurements along vertical axis (up/down)

The selected axis determines whether the angle applies to horizontal or vertical position.

Measurement Angle

Field: "Measurement angle" Range: -180° to +180° Indicates: Angle for next import or capture operation

How it works:

  • If Horizontal axis selected: angle applies to horizontal position (vertical = 0°)
  • If Vertical axis selected: angle applies to vertical position (horizontal = 0°)
  • The field shows which axis is active: "(horizontal)" or "(vertical)"

Restrictions:

  • Disabled until on-axis (0°, 0°) measurement exists
  • Requires valid LinFIR license
  • Must import on-axis measurement first before adding off-axis angles

Per-Measurement Actions

Each measurement in the table has two action buttons:

Export Button (⬇)

Click to export this specific measurement:

  1. Opens export format dialog
  2. Choose WAV or TXT format
  3. Option to include distortion metadata
  4. File is saved with angle suffix (e.g., Driver1_v0h30.wav, Driver1_v-15h0.wav)

Delete Button (❌)

Remove a measurement from the driver:

  • Off-axis measurements: Can be deleted freely
  • On-axis (0°, 0°) measurement: Can only be deleted if all off-axis measurements are removed first
    • This restriction exists because the on-axis measurement serves as the reference for all filter calculations

Tooltip guidance:

  • Enabled: "Delete measurement"
  • Disabled: "Delete all off-axis measurements first"

Export All Button

Button: ⬇ Export All Location: Above "Measurement angle" field Purpose: Export all measurements in a single operation

How it works:

  1. Click "⬇ Export All"
  2. Select output directory in file dialog
  3. All measurements are exported as WAV files
  4. Files use consistent naming: DriverName_v{vertical}h{horizontal}.wav

File naming examples:

  • On-axis: Driver 1_v0h0.wav
  • Horizontal +30°: Driver 1_v0h30.wav
  • Vertical -15°: Driver 1_v-15h0.wav
  • Horizontal -45°: Driver 1_v0h-45.wav

Format:

  • All files exported as WAV (32-bit float, mono)
  • Sample rate matches original measurement or importation sample rate
  • Distortion metadata option applies to all files
  • No individual format selection (always WAV)

Benefits:

  • Fast export of complete measurement sets
  • Consistent naming for re-import or external processing
  • Files can be re-imported via batch import with automatic angle detection

Use cases:

  • Archiving complete measurement sets
  • Sharing measurements with collaborators
  • Processing measurements in external tools (FIR Designer, Matlab, etc.)

Symmetry Tool

Button: ⚖ Symmetry Location: Below each column Purpose: Automatically duplicate measurements to opposite angles

How it works:

  • Horizontal Symmetry: If you have +30°, creates -30° by mirroring the measurement
  • Vertical Symmetry: If you have +20°, creates -20° by mirroring the measurement

Use case: Save measurement time by capturing one side and mirroring to the other side, assuming the speaker has symmetric radiation.

The Enclosure and the Rotation Center

Location: the Enclosure card, at the top right of the window, and the drawings under it (polar mode). Its settings are in four columns: the enclosure and the microphone; its shape; this driver's elements; how it stood in the horizontal and vertical planes, and its place in a system. Click its title to fold it. Purpose: describe, once, the speaker the drivers are mounted in and how it stood while its polar measurements were taken. Everything LinFIR does with off-axis measurements depends on it.

A polar measurement is a set of responses taken all around a speaker. For them to sum into the right directivity, LinFIR has to know where each driver was relative to the microphone at every angle. The angle alone doesn't tell it:

  • The turntable axis is rarely at the front baffle. Most turntables turn the speaker about a point under the cabinet, so off axis the microphone is actually further away and sees the driver at a wider angle than the nominal one. With the baffle 150 mm in front of the axis and the microphone at 1 m, the 90° measurement is really taken 16 cm further away - 0.47 ms late and 1.3 dB low - and 97° off the driver's axis; at 180° it arrives 0.88 ms late.
  • The drivers are not at the same place. A woofer 200 mm below the tweeter is closer to a microphone below the axis and further from one above it. These differences of a few tenths of a millisecond are what makes the lobes of a multi-way speaker: wrong timing gives wrong off-axis sums, and a wrong Listening Window, predicted in-room response and directivity index.
  • Some files carry no timing at all. An FRD exported without its delay, or a minimum-phase response, has lost the time of flight: the geometry is the only way to put it back.

The enclosure answers all of it: its shape, where each driver's cones are on it, what the microphone faced, and where the turntable axis was. From it LinFIR rebuilds each off-axis measurement as if the speaker had turned about the point the microphone faces, puts back the timing that files lost, places the elements of the near-field splicing, and places speakers relative to each other in a system.

IR window in polar mode IR window in polar mode

By default, every driver of a project is mounted in one enclosure, Speaker, which is the system's reference. Until it is described, it changes nothing: every cone is at the centre of its front, and so is the turntable axis and the point the microphone faces. Describe it as soon as you take polar measurements - the drawings show at once whether it matches the setup.

The enclosure

Mounted in chooses the enclosure the driver is mounted in - one of the project's, or a New enclosure (a subwoofer separate from the satellite). The drivers of one speaker share its enclosure: its shape, its turntable placement and the microphone are set once, for all of them.

SettingWhat it is
Rotation correctionRebuild the off-axis measurements from the geometry (on), or use them as they are (off).
ShapeA Box (width, height, depth, optional lean and baffle tilt) or a Sphere (radius), and the front edges (sharp, chamfer, round-over) the splicing's diffraction model uses.
HeightsShow the heights on the enclosure from its base (its bottom face) or from its middle - never above the floor.

This driver lists where this driver's radiating elements are on the enclosure: one Cone per physical driver - two for a pair of mids in parallel - plus the vents and passive radiators it drives. Each has a face, a position on it (across and height for the front), and its Sd. A vent's Outline is Round or Rectangle - a slot, its Size width × height along the face's axes, its Sd their product (see Near-Field Splicing). ↕ duplicates one mirrored about the reference point's height, for the second mid of an MTM. The correction uses the cones' centre, weighted by their Sd (their plain centre when the Sd are unknown); the splicing places each element on its own.

Rebuild the timing, under Rotation correction, shown once the driver has imported measurements (a capture always has its time of flight), is for measurements that carry no time of flight - see Timing: kept or rebuilt.

The microphone

Microphone → Aimed at sets what the microphone faced at 0°, in both planes - the reference point of the off-axis angles:

  • A driver of the enclosure, usually the tweeter: the point follows the centre of its cones, wherever they are moved. Across and Height then only show it.
  • Free point: Across and Height set it by hand, on the plane of the front face. It can be outside the enclosure: a subwoofer measured with the microphone on the satellite's tweeter axis, above the sub, faces a point above its top.

Where the microphone is aimed moves neither the enclosure nor the turntable axis.

Calculation distance, under it, is where the results are heard from, for the whole project - see The calculation distance. 2000 mm in a new project; off in a project from before 1.5.2, its value then greyed.

How it stood for each plane

SettingWhat to enter
MeasuredVertical plane only: On the turntable (the enclosure lying on a flank) or Copy of horizontal (the vertical measurements are copies of the horizontal ones - see below). The horizontal plane is always measured on the turntable.
Lying onVertical, on the turntable: the flank on the table, seen from the front.
Axis depthHow far the front face is in front of the turntable axis. Positive when the axis is behind it (the usual case).
Axis offsetWhere the turntable axis is from the centre of the front face: to the right (horizontal) or toward the top of the enclosure (vertical). 0: under the middle of the enclosure.
Mic distanceFrom the point the microphone faces to the microphone, at 0°.

When the turntable axis goes through the point the microphone faces - axis depth 0, and the axis offset equal to that point's position from the centre of the front - the measurements were taken where they should have been: nothing is corrected, whichever driver is measured. Only their timing is rebuilt, when it was removed.

Copy of horizontal is for subwoofers: in their band they radiate nearly the same in every direction, and they are often too large to lay on their side. Their vertical measurements are then copies of the horizontal ones, read with the horizontal geometry turned a quarter turn. With Rotation correction on, the copies are rebuilt as seen from far away in the vertical directions, as an enclosure placed in a system: each direction keeps the level of the horizontal measurement at its angle, and the driver's height under or above the reference point sets its timing. No microphone stood on a vertical circle around that point, which can pass through the enclosure when the point is far from the driver (a sub on the floor, measured with the microphone at 1 m). At a calculation distance too: they then keep the level and timing of the circle's on-axis point, as the horizontal plane has there.

Angles. Positive horizontal angles turn the table counter-clockwise seen from above, which brings the microphone toward the enclosure's left. Positive vertical angles put the microphone above the axis: lying on the left flank the table turns counter-clockwise for them, on the right flank clockwise - an auto-scan turns the table the right way by itself. The drawings make a table wired the other way obvious.

Timing: kept or rebuilt

LinFIR needs to know whether each driver's measurements carry their time of flight:

  • Kept - captures with a timing reference (a loopback or an acoustic reference), and files exported with their delay: the measurements are used as they are, and the correction moves them from where they were taken.
  • Rebuilt - files exported without their delay (each angle's arrival moved to the start), and minimum-phase responses: turn Rebuild the timing on. For each measurement, LinFIR puts back the time of flight a timing reference would have recorded: the distance from the driver's cones to where the microphone was at that angle, less the distance from the microphone to the point it faced at 0°. The driver aimed at, on axis, gets nothing. Then the measurements are corrected like captured ones.

The FRD to IR Converter asks the same question (Timing: Kept or Removed) and sets this switch; Minimum Phase implies Removed. No position is ever entered when importing: they all come from the enclosure. The converter's Delay still sets when each converted response starts; with a rebuilt timing it must leave room for the angles where a driver is closer to the microphone than the point it faced - a ⚠ says when it doesn't. FRD files imported with versions before 1.5.0 had the driver offsets of the converter applied into their response: import them again to use the enclosure instead.

The drawings

Under the Enclosure card, one card per plane, which folds away like it (the open ones share the height; a vertical copied from the horizontal has none): the setup in perspective (drag to turn the view) and seen from above, turned to the measurement angle - the one selected, or during a scan the angle the turntable reports. This driver's elements are drawn in colour, the other drivers' of the enclosure in grey, the microphone in blue with its line to the reference point. The front edges are drawn as set: chamfered or rounded over. In a system, the other enclosures are drawn in grey where they stand, in the horizontal plane. At 0°, seen from above, drag the turntable axis to where it is under the enclosure and the microphone toward or away (its distance) or, on a free point, across (the point of the front it faces); the fields follow.

The calculation distance

Calculation distance, in the Microphone group, is the distance the results of the whole project are calculated at: every driver's measurements are rebuilt as heard from a circle of that radius around the reference point (the system's, in a system of enclosures). It is one setting for the project, not one per graph: the filters, the alignment, the corrections, their Listening Window and Predicted In-Room references, the off-axis curves, the CTA-2034-A curves and the directivity sonogram all use the same rebuilt measurements, calculated once. The main window's Graphs menu and the Directivity Analysis window show it under their curves.

Why it matters. The drivers of a speaker are not at the same place, so the paths from them to the listener differ, and differ less the farther the listener is: on the tweeter's axis, a woofer 200 mm below it is 19.8 mm farther at 1 m but 10.0 mm at 2 m - 29 µs less, 26° of phase at 2.5 kHz - and it is seen from 11° above its own axis at 1 m, 6° at 2 m. The sum at the crossover, the lobes and the curves are those of the distance they are calculated at. ANSI/CTA-2034-A measures at 2 m (the far field of typical speakers begins there, and listeners sit nearer 3 m): a new project calculates at 2000 mm, from measurements taken at 1 m.

The level and the timing stay those of the measurement. Moving 1 m away would lower everything by 6 dB and delay it by 2.9 ms: the rebuilt measurements are brought back to the level and the time of flight the reference point was measured with, so a driver on the reference point is left as it is, whatever the distance - but for its bass, which comes from ahead of the baffle (see The bass in How it works below) -, and only the differences between drivers and directions change. CTA-2034-A reports its levels the same way, as at 1 m.

Out of the plane. A driver above or below the horizontal plane - the woofer under the tweeter - is seen from another angle across that plane at the calculation distance than it was measured at. Its other plane's measurements give the change of its response between the two directions: its power in any direction is taken as its two planes' at the same angle off its axis, weighed by how far the direction turns toward each plane (an elliptical interpolation), smoothed over 1/6 octave. Near the axis the change follows the vertical measurements; at 90°, where the angle off the axis no longer changes, nothing changes. With one plane measured, the driver is taken as symmetric about its axis.

Closer than measured. The measurements hold the drivers' radiation as seen from where they were taken: rebuilt closer, the near field of a large driver is missing - a ⚠ says so.

A circle through an enclosure. The listening points are on a circle around the reference point - the system's, in a system of enclosures - not around each enclosure. A subwoofer under the satellite whose tweeter is the system's reference point has the tweeter above it: at 1 m, the vertical circle goes down to 1 m under the tweeter, through the subwoofer's cabinet. No one listens from inside a cabinet, and a driver's sound rebuilt there in 1/r would be the sound against its cone: in that plane, the enclosure's drivers are seen from far away instead, keeping the level and timing of the circle's on-axis point. Listening points inside names the enclosure, the plane and the angles inside it (vertical, −117° to −91° for a 1 m tall subwoofer 190 mm under the tweeter, at 1 m); its hover text gives the distance from which the circle stays outside. A copied vertical, seen from far away anyway, is not mentioned. Without a calculation distance, a circle through an enclosure is seen from far away too.

Turned off - the setting of a project from before 1.5.2 - every enclosure is calculated at its own microphone distance and an enclosure placed in a system is seen from far away (see below): its results don't change until it is turned on.

A system of enclosures

Enclosures that play together - a subwoofer under a satellite - can be summed with their real relative delays and levels at every angle. The first enclosure is the system reference: its reference point is the centre of the listening positions (Make it the system reference in the System group moves the role to another one). Every other enclosure says where it is relative to it: its reference point Right, Up and Forward of the system's, and how far it is Turned. With a calculation distance, their drivers' measurements are rebuilt as heard from the system's circle of that radius, like the reference enclosure's: a subwoofer 600 mm below the satellite is 88 mm farther from a listener 2 m in front of the satellite, and seen from 17° above. Without one, they are rebuilt as seen from far away in each of the system's directions: each direction takes the driver's own response in that direction, with the level and timing of its on-axis measurement, delayed by the difference of its path to a far listener (its position from the system's centre, projected on the direction). The offsets between enclosures change the delays, not the levels: a subwoofer 1 m below the satellite keeps its directivity, where the satellite's 600 mm measurement circle would pass 0.4 m from it and read 9 dB louder there. A subwoofer whose vertical measurements are copied from the horizontal ones has the same vertical and horizontal directivity, but for the delays. For the sum to be right, the enclosures must be measured with the same timing reference (a loopback) and their levels must match (an SPL calibration, or a level offset).

How it works:

For each nominal angle, LinFIR rebuilds the response the microphone would have picked up on the ideal circle around the reference point (or the system's):

  1. Geometry, per driver. From the enclosure and the plane's pose, the real microphone positions (the 0° position turned about the turntable axis) and the ideal ones are known, so is the direction and distance at which each measurement saw the driver's acoustic centre, and the direction and distance each nominal angle needs. Distances are in 3D: a woofer 20 cm below the microphone's height is further from it at every angle. The driver's own position matters: correcting a woofer 20 cm below the tweeter as if it were at the reference point would still leave 20-55 µs of timing error, about 20-56° of phase at 3 kHz.
  2. Distance: time of flight and level. Around the driver, changing the distance only delays and scales the sound: each measurement is moved to the target distance with a fractional delay of (target distance − measured distance) / 343 m/s and a gain of measured distance / target distance (1/r law). At a calculation distance other than the microphone's, the result is brought back to the reference point's measured level and time of flight (see The calculation distance). The 1/r law holds in every direction in the far field of the driver, whatever its directivity: its pattern no longer changes with the distance, and the power through a sphere stays the same.
  3. The bass, from where it comes from. Below a few hundred hertz a cabinet radiates as if from a point ahead of its baffle, not from its cones: its low-frequency acoustic centre (J. Vanderkooy, AES 128th Convention, 2010), 13 cm ahead of the baffle of a 24 L closed box with an 8 in woofer. Moved from the cones, measurements keep the balance between front and back of the distance they were taken at: taken at 1 m and rebuilt at 2 m, that box's bass came out 0.6 dB too high on axis (1.9 dB from 0.5 m). LinFIR finds that point from each driver's own measurements, where the microphone really was: at each frequency, the point from which their levels fall off as 1/r. Where such a point describes them, the bass is moved from it; where the cabinet starts to beam and none does (from 130 to 240 Hz for that box), from the cones, the two blended in between. Checked against a boundary-element solution of that box, measured at 1 m on a small turntable and rebuilt at 2 m, the woofer's error from 50 to 200 Hz drops from 0.3 to 0.1 dB RMS. It needs measurements all around the driver: from fewer than 8, or none beyond ±90°, the point can't be told from the cabinet's beaming, and the bass is moved from the cones. A near-field spliced bass is heard from the cones already: the point found is the cones', and nothing changes.
  4. Angle: interpolation. The response in the needed direction is interpolated between the two measurements whose directions bracket it - after both were moved to the target distance, so they arrive together. The level is interpolated as a power (the squared magnitudes, weighted by how close each direction is) and the phase is the one of the interpolated complex responses. Where the angular step is too coarse for the pattern - the diffraction ripples off axis and behind the cabinet, at high frequency, are finer than 10° - the two measurements are no longer in phase, and averaging them as complex responses would cancel part of them and dig notches that aren't there; averaging their powers keeps the level. Where they are in phase, both give the same response. Beyond the measured range the nearest measurement is used; a full 360° set wraps around.

A measurement taken where it should have been is left as it is - the on-axis one, for an enclosure on its own; at a calculation distance, its bass still changes when it comes from ahead of the baffle. A scan records the angle the turntable reported for each capture; the correction places the measurement there (the list still shows it at its nominal angle). The correction applies after the IR time window and before resampling, so everything downstream (filters, sums, directivity graphs, Listening Window, DI) uses the corrected responses; the measurement files themselves are not modified, and turning the correction off restores the original responses. Symmetry copies are recognized and treated as the mirror image of the measurement they were copied from. A spliced measurement is spliced first, at the real microphone position, then corrected like the others.

Projects from before enclosures: each driver's turntable offsets (and its splicing geometry, when it had one) become an enclosure when the project is opened; drivers with the same turntable placement share one, and drivers without any get an enclosure that changes nothing. Check the drawings once.

Requirements and limits:

  • The measurements must keep their relative timing (a fixed acoustic or loopback timing reference, the same for every angle - see Impulse Response Timing Requirements), or have it rebuilt (Rebuild the timing). A rebuilt timing is the geometry's: it knows nothing of the acoustic centre's recess behind the baffle, which a measured timing includes. The near-field splicing needs measured timing.
  • The driver is treated as a point source at its acoustic centre on the baffle - in its bass, at the point its measurements give (see above): the centre's recess behind the baffle and the driver's own near field are ignored. At 1 m and beyond this is accurate for typical drivers; very close measurements of large drivers are less so. Several cones of one way are a point source at their centre, which only holds far enough from them. Between the bass and the range where the cones describe the cabinet (about 200 Hz to 1 kHz for a 24 L box), neither does: its diffraction changing with the distance is left as it is there (about 0.25 dB RMS from 1 m to 2 m).
  • The correction moves the microphone, not the diffraction: when the microphone distance is small, the baffle diffraction seen at the real and ideal positions differ slightly, and that difference is not corrected. A microphone above or below the driver's plane is accounted for in the distances; in the direction only at a calculation distance (see Out of the plane), where the angle across the plane changes.
  • Measurements off both planes are left as they are.

Workflow for Off-Axis Measurements

  1. Describe the enclosure - its shape, each driver's cones, what the microphone faces, and where the turntable axis is - in the Enclosure section and the drawings (see The Enclosure and the Rotation Center). Measure where the axis is before turning the table.
  2. Import or capture on-axis measurement (0°, 0°)
  3. Select axis (Horizontal or Vertical)
  4. Set measurement angle (e.g., +30°)
  5. Import file or capture measurement
  6. Repeat for additional angles
  7. Use Symmetry tool to fill opposite angles (optional)
  8. Analyze directivity patterns in main application graphs

🔄 Automated workflow: If you have a motorized turntable (Pololu Tic or GRBL/Arduino), use the ▶ Scan button to rotate and measure all angles automatically. See Auto-Scan with a Rotation Table and Rotation Table Settings.


Near-Field / Far-Field Splicing 🔒

Available in: every mode except Room Calibration (Loudspeaker Design, Hypex FusionAmp) License required: Valid LinFIR license

Section: Collapsible header Near-field measurements (splicing), directly under the measurement list. Collapsed by default. The splicing uses the driver's enclosure and turntable placement (polar mode), predicting each angle at the real microphone position.

Splicing synthesizes a full-range anechoic response by combining near-field captures of each radiating element (driver, vent, passive radiator) with this driver's far-field polar measurements — the Don Keele method. The near field covers the bass, where a gated far-field measurement can't; the far field covers everything above the transition, with its real diffraction and directivity. Once applied, the spliced IR replaces the raw capture for every measured angle throughout LinFIR. An angle captured or imported afterwards (including a re-import over an existing one) is spliced again automatically with the same recipe.

The section shows each near-field element's capture status and the Open splicing wizard… button (enabled once an on-axis far-field measurement exists).

The wizard is documented on its own page: Near-Field / Far-Field Splicing — prerequisites, the seven steps, and step-by-step advice.

When a spliced IR is active, the IR Windowing section below applies the driver's time window on top of the spliced (anechoic) response rather than the raw capture — a note in that section flags this.


Import from File

Load impulse responses from external files.

LinFIR works internally with impulse responses (IRs). All imported files are ultimately converted to an IR before being used for filter design. Two import paths exist:

  • Direct IR formats (WAV, TXT, TMD): Files already contain time-domain impulse response samples. They are resampled to the project sample rate and loaded directly.
  • Frequency-domain format (FRD): Files contain frequency response data (magnitude + phase). LinFIR reconstructs an impulse response via the FRD to IR Converter window before proceeding.

All the measurements of a driver share one sample rate. A file, an FRD conversion or a capture at a different rate than the driver's existing measurements is refused with a message: import or re-measure it at the driver's rate, or start a new driver. Files containing NaN or infinite samples are refused as well. The rate of a file only becomes the driver's once the file is actually stored: an import that is refused, rejected, or discarded at the low-signal warning leaves the driver's measurements and sample rate as they were.

Supported Formats

WAV Files

  • Channels: Mono or stereo (left channel used for stereo files)
  • Bit depth: 16-bit, 24-bit, or 32-bit PCM
  • Automatic resampling: The IR is resampled to match the project sample rate for processing. The original samples are preserved internally at their native rate, so changing the project sample rate later does not cause quality loss from successive resamplings. This is handled transparently in the background.

With distortion metadata:

  • If WAV contains custom 'dist' chunk (exported from LinFIR with "Include dist." option)
  • Enables THD (Total Harmonic Distortion) computation

Without distortion metadata:

  • Standard WAV import
  • Only practical/cropped IR available
  • THD computation not available

TXT Files

Plain text files containing impulse response samples, one value per line or space/comma-separated. LinFIR auto-detects this format.

Note: .txt files containing FRD-formatted data (3 columns: frequency, magnitude, phase) are automatically detected and processed as FRD files (see FRD Files section below).

TMD Files

MATAA (Mat's Audio Analyzer) time-domain data format. Each line encodes a sample with its timestamp, allowing the sample rate to be derived from the data itself.

  • Format: Two-column text file (time in seconds, amplitude)
  • Comments: Lines starting with * are metadata/comments
  • Sample rate: Inferred from the time intervals between samples. If the result is within 1% of a standard rate (44.1, 48, 88.2, 96, 176.4, 192, 384 kHz, etc.), LinFIR snaps to that exact rate to correct for the systematic sample rate error introduced by limited timestamp precision.
  • Timestamp precision: Timestamps must have enough decimal places for accurate sample rate inference (e.g. 9 digits for 96 kHz). Insufficient precision can produce a slightly off sample rate that will still be corrected if it falls within the 1% snapping tolerance.
  • Precision: Full floating-point precision (no bit-depth limitations)

Example TMD file:

* TMD data written by MATAA
* Measurement description
0.000000000	0.000000
0.000020833	0.125000
0.000041667	0.850000
...

CLIO Files

Time-domain impulse response exports from CLIO (Audiomatica) measurement software. These are plain .txt files with three columns.

  • Format: Text file with a header row followed by data rows
    • Column 1 — Time[s]: sample timestamp in seconds
    • Column 2 — Real[Pa]: signal amplitude (used as the IR)
    • Column 3 — Imag[Pa]: imaginary part (ignored by LinFIR)
  • Header line: the first non-empty line must start with Time (case-insensitive)
  • Sample rate: inferred from the time intervals between samples, then snapped to the nearest standard rate within 1% tolerance (same algorithm as TMD)
  • Precision: full floating-point precision

Example CLIO file:

Time[s]         Real[Pa]        Imag[Pa]
0.000000E+00    -4.790139E-03   -4.583853E-10
2.083333E-05     4.526122E-03   -8.076313E-10
4.166667E-05     3.454284E-04    1.007265E-10
...

FRD Files

Frequency response data files (commonly exported by REW, VituixCAD, or provided by manufacturers). These files do not contain an impulse response directly—LinFIR reconstructs one via the FRD to IR Converter window (see dedicated section below).

Format:

  • 3 columns per line: Frequency (Hz), Magnitude (dB), Phase (degrees)
  • Text-based, space or tab delimited
  • Can use either .frd extension or .txt extension (auto-detected)

Processing:

  • Automatic interpolation to required frequency points using PCHIP (Piecewise Cubic Hermite Interpolating Polynomial)
  • Configurable magnitude extrapolation for DC and high-frequency regions
  • Phase handling with group delay compensation

Extrapolation Modes:

When importing FRD files, LinFIR opens the FRD to IR Converter window with the following extrapolation controls:

  • DC Extrapolation: Controls how magnitude is extended below the lowest measured frequency

    • Constant: Flat extrapolation (holds the lowest measured value)
    • Roll-off: Applies a 12 dB/octave high-pass roll-off for realistic loudspeaker behavior
    • Default: Roll-off
  • High Frequency Extrapolation: Controls how magnitude is extended above the highest measured frequency toward Nyquist

    • Constant: Flat extrapolation (holds the highest measured value)
    • Roll-off: Applies a 12 dB/octave low-pass roll-off, automatically compensates for upward slopes
    • Default: Constant

Benefits of Roll-off mode:

  • More realistic impulse responses from incomplete FRD data
  • DC roll-off mimics natural loudspeaker low-frequency limitations
  • HF roll-off prevents artifacts from measurements that don't extend to Nyquist
  • Adaptive: compensates for incorrect slope trends in measured data

Important notes:

  • FRD files are sparse (often logarithmically spaced frequency points)
  • Requires complex interpolation, potentially introducing artifacts
  • Generally do not contain the time of flight required to properly time align drivers
  • Recommendation: Prefer importing impulse responses (WAV) whenever possible

Automatic Noise Truncation

Once an impulse response has been imported or reconstructed (from any format), LinFIR automatically truncates it to optimize file length and processing performance. This is an internal post-processing step applied uniformly to all IR data before it is stored in the project.

Truncation Algorithm:

  1. Peak detection: Locates the main impulse peak (maximum absolute value in the IR)
  2. 5-second limit: Truncates the IR to 5 seconds maximum after the peak
    • Corresponds to approximately 1.7 km acoustic distance
    • Sufficient for capturing full decay in most practical scenarios
  3. Noise threshold: Removes trailing samples below 0.1% of peak amplitude
    • Adaptive threshold based on the actual signal level
    • Eliminates noise floor without affecting useful signal
  4. Minimum duration: Always preserves at least 1.0 seconds of the IR
    • Ensures sufficient data for low-frequency analysis

Benefits:

  • Reduces processing load for FFT operations and convolutions
  • Decreases file sizes for project saving and export
  • Removes unnecessary noise floor that doesn't contribute to filter design

What gets removed:

  • Excessive silence beyond 5 seconds after the main impulse
  • Noise floor below the 0.1% threshold (≈ -60 dB relative to peak)
  • Applies to both anechoic and in-room measurements

What is preserved:

  • The complete main impulse and initial decay
  • At least 1.0 seconds of IR data regardless of noise level
  • All frequency content relevant for crossover design
  • Sufficient time-domain information for phase analysis

Impulse Response Timing Requirements

Peak delay limit: LinFIR rejects impulse responses where the main peak is located more than 200 ms after the start of the file.

Why this limit exists:

LinFIR performs extensive signal processing operations—FFT transformations, convolutions, resampling, and real-time filter preview—that must remain responsive. These operations scale with impulse response length, and excessive zero padding before the actual signal significantly impacts performance without adding useful information.

Physical context:

A 200 ms delay corresponds to approximately 68 meters of acoustic travel distance. In practical loudspeaker measurement and room calibration scenarios, such excessive delays indicate that no timing reference method was used during capture (loopback trigger, electrical reference, or pre-alignment in the measurement software).

Impact on workflow:

Without proper timing reference, relative time alignment between drivers becomes unreliable, as the arbitrary delays vary unpredictably between measurements. This compromises crossover phase coherence and summation accuracy—core functions of LinFIR.

Best practice:

When capturing impulse responses, use measurement software that provides:

  • Loopback triggering (audio interface output → input reference)
  • Electrical reference triggering (synchronized start)
  • Pre-alignment features that position the IR peak near the beginning of the recording

These methods ensure minimal file length while preserving the precise time-of-flight information needed for accurate driver alignment and filter design.

If your measurement contains a valid signal buried in initial silence, pre-process the file to remove leading zeros before importing into LinFIR.

Import Signal Level Check

When importing a WAV/TXT impulse response that wasn't captured by LinFIR's own sweep engine, the frequency response level is checked: if its peak magnitude is below -25 dB, that's usually a sign of a poor signal-to-noise ratio in the original measurement.

What happens:

  • An always-on-top Low Signal Level Warning dialog appears, offering Keep Anyway or Discard
  • Keep Anyway imports the file as usual
  • Discard cancels the import — nothing is stored, and you can re-import a different file
  • The file is not imported until you answer the dialog

Why this matters: correction filter quality strongly depends on measurement quality. A low signal-to-noise ratio means noisier data, which can produce inaccurate correction filters and skew phase visualization — see Quality Validation for the same check applied to LinFIR's own captures.

💡 Settings → General → Always keep low-SNR measurements skips this dialog and imports low-level files automatically, with only a toast as a reminder. See General Settings.

This check only applies to files not captured via LinFIR's own sweep engine — an IR that already carries LinFIR's own capture metadata skips it, since its quality was already validated at capture time. It's independent of the peak delay check above: a file can fail either, both, or neither.

Import Workflow

  1. Click "📁 Import" button
  2. Select WAV, TXT or FRD file
  3. File is automatically detected and processed:
    • WAV: Resampled to project sample rate, metadata extracted
    • TXT (impulse samples): Either auto-imported (with metadata) or user prompted for sample rate (the prompt proposes the driver's sample rate); the file is then stored at the angle in its name. In a multi-file batch, a TXT file without a sample rate is skipped, with a message
    • TXT/FRD (frequency data): Opens FRD to IR Converter window
  4. IR appears in impulse response graph
  5. Manually enter IR name in text field
  6. Apply windowing if necessary (see Time Windowing section)

Special case for FRD files: When importing .frd or FRD-formatted .txt files, the FRD to IR Converter window opens automatically. See the dedicated section below for details.

⚠️ Display Mode Check: If the imported impulse response does not appear in the graphs, verify that Drivers/Measurements display mode is selected in the graph toolbar (not FIR, IIR, or FIR+IIR modes which only show filter responses). The graph title and legend clearly indicate which mode is active.


Batch Import of Multiple Measurements

Available in: Loudspeaker Design mode (off-axis measurements) License required: Valid LinFIR license needed for off-axis measurements

Overview

Batch import enables importing multiple measurement files simultaneously with automatic angle detection from filenames. This significantly speeds up the workflow when importing multi-angle measurement sets from tools like VituixCAD, ARTA, or REW.

Filename Angle Parsing

LinFIR automatically detects measurement angles from filenames using conventions from other measurement software.

Important: Angle patterns must be at the end of the filename (before extension). If the axis marker (h/v) has a prefix format (like h30), it must not be preceded by a letter. This prevents false detection in cases like "Driverh30" while allowing "SIG270-4h30" or "Driver 2_h30".

Format with single axis specification (H = Horizontal, V = Vertical):

  • H30, h30, H-20 → Horizontal axis, angles: +30°, +30°, -20°
  • V15, v15, V-45 → Vertical axis, angles: +15°, +15°, -45°
  • 30H, 30h, -20H → Horizontal axis, angles: +30°, +30°, -20°
  • 15V, 15v, -45V → Vertical axis, angles: +15°, +15°, -45°

Format without axis (@ marker):

  • @30, @-20, Tweeter@15 → Angle detected, axis must be specified by user
  • When files use @ notation, a dialog prompts you to select Horizontal or Vertical axis

MF 2D format (both H and V in filename):

  • v0h30, V0H30, v000h030 → Horizontal +30° (horizontal plane: V=0)
  • v30h0, V30H0, v030h000 → Vertical +30° (vertical plane: H=0)
  • h30v0, H30V0, h030v000 → Horizontal +30° (order-independent)
  • h0v30, H0V30, h00v030 → Vertical +30° (order-independent)
  • v0h0, V0H0, v000h000 → On-axis (0°, 0°)
  • v30h50 → Rejected (out-of-plane measurement)

Note: Leading zeros are supported (e.g., 030 = 30)

Note on MF 2D format: Only measurements in a plane are accepted (one angle must be 0). Files with both H and V non-zero are skipped, with a message naming them, as they represent oblique measurements that can't be represented in LinFIR's horizontal/vertical coordinate system. The order of h/v doesn't matter.

Examples of valid filenames:

  • Tweeter_h0.wav → On-axis (0°, 0°)
  • Tweeter_h30.wav → Horizontal +30°
  • Tweeter_v-20.frd → Vertical -20°
  • Woofer@15.txt → Angle +15° (user selects axis)
  • measurement_30h.wav → Horizontal +30°
  • Left_-45v.frd → Vertical -45°
  • Driver_v0h45.frd → Horizontal +45° (MF 2D format)
  • Tweeter_v20h0.txt → Vertical +20° (MF 2D format)
  • SIG270-4h30.frd → Horizontal +30° (number before axis letter is OK)
  • SIG270-4v0h30.frd → Horizontal +30° (MF 2D with number prefix)

Examples of rejected filenames:

  • Driverh30.wav → Rejected (letter "r" directly before "h")
  • Testh30v0.frd → Rejected (letter "t" directly before "h")

Files without angle markers:

  • A single file goes to the angle currently selected in the window's angle controls, or to the on-axis (0°, 0°) slot while the driver has no on-axis measurement yet
  • In a multi-file batch, it is imported as the on-axis (0°, 0°) measurement

Without a license: files whose name gives an off-axis angle (_h30, v0h30, @15...) are skipped, even a single file into a driver with no on-axis measurement yet, with a message naming each file and the angle read in its name; the on-axis ones (no angle, _h0, @0...) are imported. A name can hold an angle by accident (Woofer_v2.wav reads as V2°): rename the file without it to import it on-axis. The axis selection dialog below is not shown.

Room Calibration: the angle in a file name is ignored: the file is imported as the position's measurement (0°, 0°).

Batch Import Workflow

1. Multi-File Selection

  1. Click "📁 Import" button
  2. Select multiple files in the file dialog (Ctrl+Click or Shift+Click)
  3. Click Open

2. Automatic Processing

LinFIR automatically analyzes all selected files:

If all files have explicit axis (H/V in filename):

  • Files are processed immediately
  • Each file imported at the angle specified in its filename
  • No user interaction needed

If files use @ notation (ambiguous axis):

  • Axis Selection Dialog appears
  • Select either Horizontal or Vertical axis
  • Click Continue
  • Selected axis applies to all @ files in the batch
  • Closing the dialog cancels the whole batch import

3. FRD Converter Integration

If the batch includes FRD files:

  1. LinFIR opens the FRD Converter for the on-axis FRD file (if present)
  2. Configure conversion parameters (sample rate, delay, extrapolation modes)
  3. Click "Use This Impulse Response"
  4. All remaining FRD files automatically use the same parameters
  5. No need to configure each file individually

How it works:

  • Parameters are configured using the on-axis measurement (0°, 0°)
  • Same delay and extrapolation settings applied to all off-axis FRD files
  • Ensures consistent conversion across the measurement set

Timing between angles:

FRD files exported without their delay lose the relative time of flight between angles: every file then starts at the same time, and the drivers' off-axis lobing would be wrong. Choose Removed under Timing in the converter: LinFIR rebuilds each angle's time of flight from the driver's enclosure (see Timing: kept or rebuilt), so describe the enclosure first. FRD files exported with their delay (a fixed timing reference) keep it: choose Kept.

Practical Example

Scenario: You have a set of horizontal measurements exported from REW:

Tweeter_h0.frd
Tweeter_h15.frd
Tweeter_h30.frd
Tweeter_h45.frd
Tweeter_h60.frd

Workflow:

  1. Select all 5 files in file dialog
  2. FRD Converter opens for Tweeter_H0.frd (on-axis)
  3. Set sample rate to 96000 Hz, delay to 5 ms
  4. Choose DC extrapolation: Roll-off
  5. Click "Use This Impulse Response"
  6. Files H15, H30, H45, H60 automatically converted with same settings
  7. All 5 measurements appear in the horizontal column

Result:

  • All angles have same delay (5 ms) configured on on-axis measurement
  • ⚠️ Relative time-of-flight differences between angles are lost
  • For accurate crossover modeling, prefer WAV impulse response files

Limitations

  • Batch import only works with files having consistent format (all WAV, all FRD, or mixed)
  • Files must follow supported angle naming conventions
  • On-axis measurement (0°, 0°) should be included when importing FRD files for optimal parameter configuration
  • If mixing WAV and FRD formats, FRD files must include on-axis or parameters will use defaults
  • FRD files don't preserve relative time delays between angles—prefer WAV files for multi-angle measurements

Tips

Consistent naming convention:

  • Use descriptive base names: Tweeter_h30.wav instead of just h30.wav
  • Include driver name in filename for easier identification
  • Use lowercase h/v for consistency with LinFIR exports
  • MF 2D format is order-independent: v0h30 = h30v0

Large measurement sets:

  • Import horizontal and vertical measurements separately if you have both
  • Use Symmetry tool after batch import to fill missing opposite angles
  • Verify measurement table after import to ensure correct angle assignment

FRD files:

  • ⚠️ Not recommended for off-axis measurements (missing relative time delays)
  • Always include on-axis (H0 or V0) measurement in batch for parameter reference
  • Configure extrapolation modes carefully for first file—settings propagate to all
  • Verify impulse response quality after batch conversion
  • Consider this a preliminary workflow—prefer WAV files for accurate directivity analysis

Recommended format priority:

  1. WAV files: Best option—preserves all timing information
  2. TXT with metadata: Acceptable if exported from LinFIR
  3. FRD files: Only for magnitude analysis—timing not preserved

FRD to IR Converter

When importing FRD files, LinFIR opens a dedicated conversion window with advanced tools for interpolation, visualization, and quality assessment.

FRD to IR Converter Window FRD to IR Converter Window

Overview

The FRD to IR Converter transforms sparse frequency-domain data into time-domain impulse responses using sophisticated interpolation and extrapolation techniques. It provides real-time visualization and quality metrics to help you assess the conversion quality.

Conversion Parameters

Sample Rate

Options: 44.1 kHz, 48 kHz, 88.2 kHz, 96 kHz, 176.4 kHz, 192 kHz Default: 96 kHz

Target sampling frequency for the resulting impulse response.

Considerations:

  • Higher sample rates provide better frequency resolution
  • Must match or exceed your project's sample rate
  • FRD data is interpolated to fill all frequency bins from DC up to Nyquist

Delay Compensation

Range: 0.0 to 100.0 ms Default: 5.0 ms

Time offset applied to the impulse response to allow for pre-ringing visualization and processing.

Purpose:

  • Provides time buffer before the main impulse
  • Essential when FRD data contains non-minimum phase characteristics
  • Allows visualization of pre-ringing artifacts

Warning indicator: If pre-ringing duration exceeds the delay setting, a warning appears suggesting either:

  • Increase delay to accommodate pre-ringing
  • Enable Minimum Phase transformation

Minimum Phase Transformation

Default: Disabled

Applies Hilbert transform to convert the impulse response to minimum phase, eliminating all pre-ringing.

When to use:

  • FRD data shows significant pre-ringing (> 5% energy before peak)
  • Phase data is corrupted, smoothed, or contains wrapping errors
  • You need a causal, physically realizable impulse response
  • Time-domain alignment is critical

Effects:

  • Removes all energy before the main peak
  • Preserves magnitude response
  • Changes phase response to minimum phase equivalent
  • Results in a causal system (no pre-ringing)

Note: Pre-ringing in FRD-derived impulses is often an artifact of measurement or file creation, not a physical characteristic of the device.

DC Extrapolation

Modes: Constant, Roll-off Default: Roll-off

Controls how magnitude is extended below the lowest measured frequency toward DC (0 Hz).

Constant mode:

  • Flat extrapolation using the lowest measured value
  • Use when FRD data already reaches very low frequencies

Roll-off mode (recommended):

  • Applies 12 dB/octave high-pass characteristic
  • Mimics natural loudspeaker low-frequency roll-off
  • More physically realistic for incomplete low-frequency data

High Frequency Extrapolation

Modes: Constant, Roll-off Default: Constant

Controls how magnitude is extended above the highest measured frequency toward Nyquist.

Constant mode (recommended):

  • Flat extrapolation using the highest measured value
  • Maintains adequate signal level to Nyquist
  • Minimizes noise amplification

Roll-off mode:

  • Applies 12 dB/octave low-pass characteristic
  • Automatically compensates for upward slope trends
  • Use when FRD data shows unrealistic high-frequency behavior

Timing

Timing says whether the FRD files carry their time of flight:

  • Kept: they were measured with a timing reference and exported with their delay. Their phase holds where each driver was relative to the microphone at each angle; the enclosure only corrects the turntable's rotation center.
  • Removed: they were exported without their delay (each response moved to the start), or Minimum Phase is on. LinFIR rebuilds each angle's time of flight from the driver's enclosure.

The choice applies to all of the driver's measurements: it is the Rebuild the timing switch of the Enclosure section. No driver position is entered here: positions come from the enclosure - see Timing: kept or rebuilt.

With Removed, the Delay must leave room for the angles where the driver is closer to the microphone than the point it faced (up to the distance between the driver and that point, 0.58 ms for 200 mm): a ⚠ next to the choice says when it doesn't.

Display Parameters

These parameters control visualization only and do not affect the conversion.

IR Start / Stop Time

Range: 0.0 ms to impulse duration Purpose: Zoom into specific time region of the impulse response graph

Useful for examining:

  • Pre-ringing characteristics
  • Main peak detail

Frequency Min / Max

Range: 1 Hz to 48000 Hz Purpose: Set frequency range for magnitude and phase graphs

Allows focusing on:

  • Specific frequency bands of interest
  • Problem areas in the response
  • Comparison between original and interpolated data

Wrap Phase

Default: Disabled

Toggles between wrapped (-180° to +180°) and unwrapped phase display.

Wrapped:

  • Phase limited to -180° to +180° range
  • Shows discontinuities at ±180° boundaries
  • Familiar format for some users

Unwrapped:

  • Continuous phase (can exceed ±180°)
  • Shows true phase accumulation
  • Better for assessing group delay trends

Remove Delay Phase

Default: Disabled

Removes the linear phase component corresponding to the delay setting.

When enabled:

  • Subtracts linear phase = -360° × f × delay
  • Reveals underlying phase structure
  • Useful for comparing final phase response with the original one

Data Quality Assessment

The converter displays comprehensive quality metrics to help you evaluate the FRD data.

Coverage Metric

Format: "X / Y frequency points (Z% coverage)"

  • X: Number of frequency points in FRD file (within 0 Hz to Nyquist)
  • Y: Expected number of points for complete FFT coverage
  • Z: Coverage percentage = (X / Y) × 100

Quality indicators:

  • ✅ Good (≥ 50%): Green - Sufficient data density
  • ⚠️ Moderate (20-50%): Yellow - Acceptable but sparse
  • ❌ Low (< 20%): Red - Very sparse, heavy interpolation required

FFT bin calculation: Based on sample rate and FFT size (4× next power of 2)

Info Button - Detailed Diagnostics

Click the ℹ Info button to open the Data Quality Information window with detailed analysis.

Missing DC (0 Hz):

  • Impact: Low-frequency extrapolation required
  • Consequence: Uncertainty in bass response below lowest measured frequency
  • Solution: Use Roll-off extrapolation for DC

Missing Nyquist Data:

  • Impact: High-frequency extrapolation required
  • Consequence: Uncertainty in high-frequency response
  • Recommended: FRD should extend to at least Nyquist frequency

Sparse Frequency Data:

  • Threshold: < 50% coverage
  • Impact: Heavy interpolation between measured points
  • Risk: Artifacts from PCHIP interpolation of widely-spaced points
  • Note: Shows exact percentage of missing data points

Pre-ringing Detection:

Analyzed automatically after conversion. Three severity levels:

  • Minor (0.1% - 0.5% energy before peak):

    • Blue indicator
    • May indicate slight phase smoothing or measurement artifacts
    • Usually acceptable for most applications
  • Moderate (0.5% - 1.0% energy before peak):

    • Yellow/Orange warning
    • Phase data likely smoothed or contains wrapping errors
    • Consider minimum phase transformation
  • Significant (≥ 1.0% energy before peak):

    • Red warning
    • Severe phase corruption or non-physical characteristics
    • Strongly recommended: Enable Minimum Phase transformation
    • Will affect transient response and phase correction accuracy

Pre-ring duration: Time span from first significant energy to main peak

Physical interpretation: Real loudspeakers cannot produce energy before the stimulus arrives. Pre-ringing in FRD files indicates:

  • Phase data smoothing in measurement software
  • Phase wrapping/unwrapping errors
  • File export artifacts
  • Non-minimum phase processing applied to data

Impact Warnings

The Data Quality Information window provides context on how issues affect the conversion:

Missing Data Effects:

  • Artifacts in reconstructed impulse response
  • Estimated information through interpolation/extrapolation
  • Final impulse may not fully represent original system

Best Practices for FRD Files:

  • Include DC (0 Hz) measurement point
  • Extend data to at least Nyquist frequency
  • Aim for > 50% frequency coverage
  • Prefer linear frequency spacing over logarithmic
  • Avoid phase smoothing in export settings

Time-Domain Preference:

The converter emphasizes: When possible, import impulse responses (WAV files) instead of FRD.

Advantages of time-domain data:

  • No interpolation artifacts
  • Preserves time-of-flight information (with proper timing reference)
  • Essential for proper driver alignment in crossover design
  • Natural representation of system behavior

FRD limitations for crossover design:

  • Often lacks time-of-flight data
  • Driver motors may not be coplanar
  • Diaphragm geometry affects acoustic center
  • Horn loading adds group delay
  • Relative delays between drivers are essential

Visualization Graphs

The converter displays three synchronized graphs:

1. FRD Data (Original + Interpolated):

  • Left: Magnitude response
  • Right: Phase response
  • Red curve: Original FRD measurements
  • Dashed blue curve: PCHIP interpolated curve

2. Impulse Response:

  • Reconstructed time-domain impulse
  • Zoom using IR Start/Stop controls
  • Shows pre-ringing and overall IR structure

3. Reconstructed Frequency Response:

  • Left: Magnitude computed from impulse via FFT
  • Right: Phase computed from impulse via FFT
  • Validation: Should closely match interpolated FRD (with Remove Delay Phase button enabled)
  • Differences indicate reconstruction issues

Workflow

  1. Import FRD file - Converter window opens automatically
  2. Review quality metrics - Check coverage and warnings
  3. Adjust extrapolation - Set DC and HF modes as needed
  4. Set sample rate - Match or exceed project sample rate
  5. Configure delay - Ensure adequate pre-ringing buffer
  6. Enable minimum phase - If pre-ringing > 1% or phase corrupted
  7. Inspect graphs - Verify interpolation and reconstruction quality
  8. Click "Use This Impulse Response" - Apply to selected measurement angle

The converted impulse is automatically stored in the driver's measurement at the specified horizontal/vertical angle.


Measurement Calibration

Microphone Calibration Selection Microphone Calibration Selection

Correct this driver's measurements for the measurement chain itself, in three independent parts (any of them, or none):

  • Microphone: the microphone's frequency response and sensitivity factor, from its calibration file;
  • Soundcard: the audio interface's own response, measured through a loopback cable;
  • Level: a level offset set by hand, and the chain's absolute sensitivity, so that the measurements read in dB SPL - see SPL Calibration.

Calibration management:

  • The microphone and soundcard calibration libraries are managed in Settings → Measurement Calibration (see Measurement Calibration), with a default of each kind for new drivers
  • The SPL calibration is measured here, per driver
  • Each driver/measurement can use different calibrations or none at all

Microphone

Compensates for:

  • Frequency response deviation from ideal flat response
  • Sensitivity factor (dB conversion from microphone output to SPL)

Options:

  • None: No calibration applied (use for reference microphones or pre-calibrated measurements)
  • [Calibration file names]: All imported calibration files from Settings → Measurement Calibration

Soundcard

Compensates for the audio interface's own response - magnitude and phase - measured through a loopback cable (see Measurement Calibration → Soundcard).

Options:

  • None: No soundcard correction
  • [Calibration names]: All calibrations measured in Settings → Measurement Calibration. Calibrations measured at another sample rate than this driver's measurements are greyed out: a soundcard calibration only corrects measurements captured at its own sample rate. If the selected one doesn't match, a warning is shown and it is not applied.

Behavior

  • Selection is saved with the project file, calibration data included
  • Changing the selection immediately recomputes the driver's measurements and all filter responses

How Calibration is Applied

The corrections are applied to each measurement before its time window, soundcard first, then microphone; the SPL calibration and level offset come after the window. Calibration Processing details the order and how each correction is built.

When to Use Calibrations

Apply a microphone calibration when:

  • Using consumer or measurement microphones with non-flat response
  • You have calibration data from the manufacturer or third-party calibration service
  • Measurements were taken with the same microphone used for the calibration file

Apply a soundcard calibration when:

  • Measurements were taken through the interface, channels, and sample rate the calibration was measured with

Use "None" when:

  • Measurements were taken with an already-flat reference microphone
  • Importing measurements already compensated externally

Per-Driver vs. Default Calibration

Per-driver assignment (this window):

  • Overrides any default set in Settings
  • Useful when combining measurements from different microphones or interfaces in one project
  • Saved with the project file

Default calibration (Settings → Measurement Calibration):

  • Automatically applied to newly created drivers/measurements
  • Does not affect existing drivers
  • See Measurement Calibration for configuration

Level Offset

A gain in dB, set by hand per driver (per measurement in Room Calibration mode), added to every measurement of the driver: captured or imported, SPL-calibrated or not. It is the Level offset field, first in the Level part of the section; its explanation is on hover.

It is for a measurement taken at a level known to differ from the others' - typically with the preamp at another gain. With the preamp 6 dB higher, the measurement reads 6 dB too loud: enter -6 dB, and it lines up with the others again. It works the same with an SPL calibration: a driver measured without calibration can take the others' (Apply to all drivers in a calibrated driver's window), with the offset making up for the gain changed in between.

The offset corrects the measurement, unlike the driver's Gain, which goes into the filters and the exports. It is saved with the project, undone and redone like any other change, and each driver keeps its own: it is not copied with a driver's parameters, nor by Apply to all drivers.

SPL Calibration

A measurement captured by LinFIR is in digital units: 0 dB is a full-scale sine at the input of the audio interface. The microphone's pressure is in it, scaled by the microphone's sensitivity, the preamp's gain and the converter. The SPL calibration measures that scale once, from a sound of known level, so that the measurements read in dB SPL.

It is per driver (per measurement in Room Calibration mode), in the Level part of the Measurement Calibration section, under the level offset.

SPL calibration of a driver SPL calibration of a driver

What it depends on

Only the input chain: the microphone, the preamp gain, the input channel of the interface, and LinFIR's input gain compensation (Audio Settings). As long as none of these changes, the calibration holds - for every driver measured through it, and across sessions.

The output side does not matter. The sweep level, the amplifier's gain and the driver's sensitivity change what the microphone hears, and that is precisely what a calibrated measurement shows: turn the amplifier up 6 dB and the next capture reads 6 dB more SPL.

When the input channel or the input gain compensation no longer match the ones the calibration was measured with, the section says so: calibrate again.

The driver's microphone calibration need not be chosen first. The calibration keeps what it read, and when the driver's mic calibration is not the one it was read with - selected afterwards, changed or removed since - it reads it again with the one the driver has: 0 dBFS = … follows, and its hover says so. This matters: a mic calibration file's curve is rarely at 0 dB at the calibrator's frequency, and whatever it shows there (a microphone reading 1 dB high at 1 kHz, say) is as much in the calibrator's tone as in the measurements. A calibration made with an older LinFIR version is read again too if it was made without a mic calibration; if it was made with one, changing it still asks to calibrate again.

Calibrating

Click Calibrate…, then choose the method.

SPL calibration panel, on a calibrator reading SPL calibration panel, on a calibrator reading

Acoustic calibrator (the more accurate one):

  1. Fit the calibrator over the microphone's capsule (with the adapter for its diameter) and switch it on.
  2. Check its level (94 dB SPL, or 114 dB on calibrators that have both) and frequency (1 kHz on most, 250 Hz on some pistonphones).
  3. Click Read the input. LinFIR plays nothing and reads the level of the third of an octave around the calibrator's frequency. It checks that the tone is there: a recording without it - the calibrator off or not fitted, another frequency - can't be applied.
  4. Click Apply calibration - while it reads, or after Stop.

The microphone can be calibrated right where it is, even at the cone for a near-field measurement: the calibrator brings its own sound.

Sound level meter + pink noise:

  1. Put the meter right beside the microphone, both pointing at the speaker, a metre or more away from it. At that distance a few centimetres between the two make no difference; close to a cone they would. Calibrate there, then move the microphone where the measurement needs it - without touching the preamp gain.
  2. Choose the output the noise plays on (the driver's output by default), and the meter's weighting. Set the meter itself to the same weighting - C, or Z (also called Flat or Lin) if it has it - and to Slow. Most meters have an A/C switch; A also works, LinFIR applies whichever is chosen.
  3. Click Play the noise. LinFIR plays pink noise band-limited to 500 Hz - 2 kHz, starting low. Raise Noise level until the meter reads 75 to 85 dB SPL - well above the room's noise.
  4. Note the meter's reading, click Stop if you like, type the reading into Meter reading and click Apply calibration.

⚠️ The noise plays from 500 Hz to 2 kHz, on the output chosen. Never send it to a tweeter or a compression driver without its high-pass filter: use a midrange, a woofer or a full-range speaker. Any speaker will do - only the sound at the microphone matters, not where it comes from.

Why this band: it is above the room's modes, below where a meter's and a measurement microphone's directivity part ways, and in it the weightings hardly differ (dB(A) reads less than 1 dB under dB(C) on this noise). A consumer meter is typically accurate to about ±1.5 dB (class 2); the calibration is as accurate as the meter.

While it reads, the panel shows the input level in dBFS (a full-scale sine reads 0 dBFS) and, when the driver already has a calibration, that level in dB SPL with it - a quick way to check a calibration against the calibrator or the meter. Stop keeps the last seconds read (Last reading): the calibration can still be applied from them, and changing the meter's weighting reads them again. A clipping input is flagged and can't be applied: turn the preamp down, and calibrate after the change.

Using it

Once applied, the section shows the calibration - for example 0 dBFS = 121.3 dB SPL, with how and when it was measured on hover - and:

  • Show in dB SPL: the calibrated measurements in dB SPL (on), or back in digital units (off). It switches every driver at once, since the drivers are summed and compared.
  • Apply to all drivers (Apply to all measurements in Room Calibration mode): gives every driver this calibration - right as long as they are all measured through the same input chain. Each driver keeps its own level offset. A driver measured with the preamp turned up gets its own calibration, made with that gain - or this one with a level offset.
  • Calibrate again… (the display stays as it was) and Remove.

The calibration is saved with the project, undone and redone like any other change, and copied with a driver's parameters.

What is calibrated

  • The measurements LinFIR captured, and only those. An imported measurement keeps its own scale (an FRD exported in dB SPL by another program already reads in SPL). When a calibrated driver's measurements are all imported, the section says so.
  • The level shown at each frequency is the SPL the sweep produced there, at its level - what the meter would read with a sine at the sweep's level playing. It is not normalized to a distance or to a voltage: to compare with a datasheet's sensitivity (dB SPL at 2.83 V and 1 m), take the voltage at the speaker's terminals and the microphone distance into account.
  • A near-field splice follows its far-field measurement's scale, so it is calibrated with it.
  • The harmonic distortion in absolute level follows the measurements; THD in percent or relative dB does not change.
  • The impulse and step responses scale up by the same factor (use Normalize to compare their shapes).
  • Exported impulse responses stay in digital units, as captured.
  • The filters don't change: corrections, Auto-EQ and the target curves all work relative to the response's own level. Auto-level only changes when the drivers have different calibrations or offsets - their levels are then corrected for the gain changed between their measurements, which is the point.

Calibrate every driver of the project, or none: shown in dB SPL next to one in digital units, a driver is about 100 dB apart and their sum means nothing. The level axis of the main window's graph reads Magnitude [dB SPL] when every active driver is calibrated.

How it works

The calibration is one number: the SPL that records as a full-scale sine, \( L_{FS} \). It is the reference level minus the level recorded:

\[ L_{FS} = L_{ref} - L_{rec} \]

\( L_{rec} \) is read in dBFS with the driver's microphone calibration applied - its frequency response, not its sensitivity factor: a calibrator's third-octave level, or the pink noise's level over 350 Hz - 2.8 kHz with the meter's weighting (IEC 61672-1). A captured measurement is multiplied by \( 10^{(L_{FS} + O + S)/20} \), \( O \) being the level offset and \( S \) the microphone calibration's sensitivity factor, which LinFIR's microphone correction subtracts; an imported one by \( 10^{O/20} \) alone.


Time Windowing

Isolate the direct sound from an impulse response and exclude reflections or noise.

Note: Time windowing is not available in Room Calibration mode. This is intentional: Room Calibration mode is designed to capture the full speaker-plus-room response, including reflections and room decay. Applying a time window would produce an anechoic-like impulse response — corrections derived from it would be wrong for the actual listening environment — what you hear is the direct sound from the speakers combined with all the reflections that follow, and the correction filters must account for that full response.

IR Windowing and Delay Compensation IR Windowing and Delay Compensation

Parameters

Start Time

Beginning of the time window in milliseconds.

  • Purpose: Remove pre-ringing or early noise
  • Typical: 0.0 to 5.0 ms before main peak
  • Effect: Sets the beginning of the extracted portion

Stop Time

End of the time window in milliseconds.

  • Purpose: Exclude late reflections or room decay
  • Typical: 5.0 to 100.0 ms after main peak
  • Effect: Sets the end of the extracted portion

Duration Display

Window duration (Stop Time - Start Time).

Start and Stop are independent — neither one drags the other. If you bring them within a taper of each other (or cross them), the fade-in and the fade-out simply multiply: the window becomes a smooth sub-unity bump rather than a malformed shape. With the default 0.5 ms taper, 4.0 ms / 4.5 ms already gives a clean triangular window (the fade-in reaches full amplitude exactly where the fade-out starts).

Time Reference

Start Time and Stop Time are defined on the raw impulse response — the measurement exactly as captured or imported, before any gain, IIR/FIR filtering, physical time delay, or delay compensation. A Start of 0 means "keep the measurement from its very first sample"; the values never change meaning as you build up filters and delays on the driver.

The Impulse Response and Step Response graphs, on the other hand, show the processed driver signal, and the red window-envelope preview (see Preview) is drawn on top of that processed curve. Since processing shifts the signal along the time axis, the window's position on the graph is offset from the number you entered:

Processing applied to the driverWhere the window appears on the graph
Crossover / correction FIR filtershifted later by the filter's own delay (the position of its impulse peak)
Time Delay (see Driver Processing)shifted later by that amount (real zero-padding of the response)
Delay Compensation (above)shifted earlier by that amount (display-only offset)

For example, with a 2 ms Time Delay on the driver and no delay compensation, a window Start of 0 ms shows its fade-in at the 2 ms mark: the window has not moved — the displayed impulse has been delayed by 2 ms, and the overlay follows it so the two stay aligned. Remove every filter and set both delays to zero and the overlay lines up exactly with the entered value.

The overlay is deliberately drawn relative to the curve beneath it, so it always shows what the window does to the response you are actually looking at rather than to an abstract time axis. Note also that with Adaptive IR display on (Graphs settings), the graph zooms to the signal and may crop the region before the impulse — if your Start sits in that cropped area, the overlay simply enters from the left edge already open.

No need to do the arithmetic yourself: hovering Start or Stop shows exactly where that value lands on the graph, with the shift broken down by cause (FIR delay / Time Delay / Delay Compensation). Whenever that shift is non-zero, an On Graph row also appears right under Window Duration, showing both shifted values at a glance — e.g. 2.00 ➡ 12.00 ms for a Start/Stop of 0 / 10 ms with a 2 ms Time Delay. This readout always uses the raw Start/Stop values as the source of truth (they never change meaning), it only translates where they currently show up.

Auto Set Window

Click "Auto Set Window" to automatically detect and configure optimal window boundaries.

How It Works:

The algorithm analyzes the on-axis measurement (0°, 0°) and automatically sets the start and stop times:

  1. Detect main peak: Locates the largest absolute amplitude in the impulse response
  2. Compute Hilbert envelope: Calculates the amplitude envelope for robust reflection detection
  3. Adaptive threshold: Adjusts detection sensitivity based on signal-to-noise ratio (3-8% of peak)
  4. Set start time: Places window start 3 ms before the main peak (clamped to 0.0 minimum)
    • This margin accounts for off-axis measurements where the sound path may be shorter (gives a margin of ~1m)
    • Prevents truncation of the direct sound in off-axis measurements
  5. Search for reflections: Scans the envelope for the first significant reflection/echo after the main peak:
    • Must occur at least 3 ms after the main peak
    • Must exceed the adaptive threshold
    • Must be a local maximum in the envelope
  6. Set stop time: Places window stop 0.5 ms before the first detected reflection

If no significant reflection is detected, the stop time is set to the end of the search window or IR length.

Detection Method:

The algorithm uses Hilbert envelope analysis to detect reflections. This provides more robust detection than simple amplitude analysis by following the overall energy contour of the signal, making it less sensitive to oscillations within the waveform.

Window Margins:

  • Start margin (3 ms): Ensures off-axis measurements are not truncated when rotating large loudspeakers. At the speed of sound (~343 m/s), 3 ms corresponds to approximately 1 meter of path length difference. During rotation, drivers may move closer to or further from the microphone—this margin provides sufficient safety for rotations of large cabinet.
  • Stop margin (0.5 ms): Small margin before the detected reflection to avoid including the beginning of the echo.

Best Use Cases:

  • ✅ Quasi-anechoic measurements: Ideal for measurements with clear, isolated reflections (e.g., outdoor, treated rooms, gated measurements)
  • ✅ Controlled environments: Works well when the direct sound is clearly separated from reflections
  • ✅ Multi-angle measurements: The 3ms start margin prevents truncation of off-axis measurements
  • ✅ Time-saving: Quick initial window setup that can be manually refined if needed

Limitations:

  • ❌ Reverberant environments: Not suitable for highly reflective rooms where reflections arrive continuously
  • ❌ Dense reflection patterns: May not detect the first reflection correctly if multiple reflections arrive in quick succession
  • ❌ Room measurements: For full-room measurements including reflections, manual windowing is more appropriate

Recommendation:

Use "Auto Set Window" as a starting point in quasi-anechoic conditions, then verify and adjust the window boundaries manually while observing the impulse response graph. In reverberant environments, set window parameters manually based on your measurement conditions.

Windowing Purpose

  • Anechoic approximation: Simulate anechoic conditions from room measurements
  • Reflection gating: Remove floor, ceiling, and wall reflections
  • Crossover and correction design: Essential for accurate filter design using measured data
  • Clean response: Isolate direct driver response

Window Function

LinFIR uses a Tukey window (tapered cosine/raised cosine) for smooth fade-in and fade-out transitions. This prevents spectral artifacts and high-frequency ringing caused by abrupt signal truncation.

Windowing Convention:

The fade-out starts at the stop parameter:

  • Fade-in: [start → start + taper]
  • Full signal: [start + taper → stop]
  • Fade-out: [stop → stop + taper]

The applied window is the product of the fade-in and the fade-out envelopes, so if start and stop are within a taper of each other the two overlap gracefully into a smooth sub-unity bump instead of a broken shape — no minimum gap is enforced.

No fade at the extremes: a fade exists only to smooth a discontinuity created by truncating real signal — a start of 0 truncates nothing before it (see Time Reference), so there is no fade-in at all in that case: the window opens at full amplitude from the very first sample. The stop side needs no equivalent special case: once stop reaches the measurement's own duration (its maximum allowed value), every real sample already falls before it, so the fade-out ramp naturally has nothing left to attenuate.

Taper Duration: 0.5 ms fixed for simple windowing. For adaptive windowing, the taper is frequency-adaptive: each band gets a half-period taper centered on its center frequency (half of 1/frequency), with a floor at 0.5 ms. This means high frequencies use ~0.5 ms tapers while low frequencies use much longer tapers (e.g., 5 ms at 100 Hz, 10 ms at 50 Hz) to match the wavelength and avoid introducing ripples in the magnitude.

Preview

The impulse response graph shows the windowed result in real-time as you adjust start and stop times.

Whenever you change a windowing parameter (start/stop time, drag, "Auto Set Window", "Reset Window", or toggling Adaptive Window), the window envelope itself is briefly overlaid in red on both the Impulse Response and Step Response graphs, scaled to line up with the peak of the curve underneath. Alongside it, on the Impulse Response graph, the raw (un-windowed) impulse response of the measurement currently shown is drawn as a dashed line in the same colour as that driver's impulse curve, so you can see directly what the window keeps and what it removes. Both fade together: fully visible for 3 seconds, then fading out over 2 seconds - changing a parameter again resets the timer. The overlay is only shown for the driver you're currently editing, and only while its window is enabled.

You can also bring the overlay up at any time without changing anything by clicking the Show window button in the IR Windowing section.

The overlay (and the dashed reference) is positioned to match the processed curve on the graph, so its start/stop will not sit at the raw Start/Stop values you entered once the driver has filters or a time delay — see Time Reference above for why.

IR Window Envelope Preview IR Window Envelope Preview

With Adaptive Window enabled, the overlay instead draws a telescoping sequence of fade-out curves, one per frequency band: the shortest (darkest, treble) band's complete window is drawn first, and each following, longer band picks up exactly where the previous one's plateau ends and extends the shape further out, growing lighter as frequency decreases. Because bass bands extend their fade-out much further in time than treble bands, you'll often only see the first few (darkest) steps within the graph's visible range - the lower-frequency ones continue further right, beyond the current time axis.


Adaptive Window

Advanced frequency-dependent windowing that preserves low-frequency response while gating high-frequency reflections.

How It Works

When enabled, LinFIR uses a wavelet transform to apply different window lengths for different frequencies:

  • Start parameter: Applied uniformly to all frequencies
  • Stop parameter: Applied with frequency-dependent extensions
    • Lower frequencies get longer decay times
    • Higher frequencies use shorter windows

Examples of automatic extensions:

  • 30 Hz: +33 ms beyond stop time
  • 480 Hz: +2 ms beyond stop time
  • 7.5 kHz: +0.1 ms beyond stop time
  • 18 kHz: +0.06 ms beyond stop time

This reflects the physical reality that longer wavelengths make it difficult to temporally separate direct sound from reflections.

Benefits

  • Preserves bass response: Low frequencies automatically get the time they need
  • Avoids bass roll-off: Short windows don't unnaturally cut off bass
  • Frequency-aware gating: Removes high-frequency reflections while keeping bass intact
  • No phase distortion: Maintains natural phase relationships

When to Use

Use Adaptive Window when:

  • Gating reflections but need to preserve bass response
  • Using short measurement windows where bass would be compromised
  • Simple windowing causes unnatural bass attenuation
  • You want frequency-dependent decay times matching physical acoustics

Don't use Adaptive Window when:

  • Working with anechoic or quasi-anechoic measurements with very clean direct sound (simple window is cleaner)
  • You have sufficient window length for all frequencies uniformly
  • You prefer uniform windowing for consistency

Enabling

Check the "Adaptive Window" checkbox in the IR Windowing section.


Delay Compensation

Shift the impulse response earlier in time without truncating data.

How It Works

  • Non-destructive: IR data remains intact in memory
  • Display offset: Delay applied as metadata for display and calculations
  • Purpose: Bring acoustic peak closer to time zero to flatten the phase

Auto Detect Delay

Click "Auto Detect Delay" to automatically detect and apply optimal delay compensation across all drivers:

Behavior:

  1. Detects the peak position for each driver (based on on-axis measurements)
  2. Finds the minimum detected delay across all drivers
  3. Applies this minimum delay to all drivers simultaneously

Advantages:

  • Preserves temporal alignment: All drivers maintain their relative timing relationships
  • Removes common delay: Eliminates the shared propagation delay from all measurements
  • Prevents errors: Ensures consistent delay compensation across all drivers automatically

Detection Method:

  • Locates the position of the main peak in the impulse response
  • Uses on-axis measurement (0°, 0°) as reference for each driver
  • Aligns all driver peaks precisely at time zero

Manual Adjustment

Manually enter delay value in milliseconds to fine-tune compensation for individual drivers.

Sync Toggle (enabled by default):

When the Sync toggle is enabled, any manual delay adjustment automatically applies to all drivers in the project. This ensures consistent compensation across all drivers without needing to adjust each one individually.

  • Enabled: Changes to the delay parameter propagate to all drivers automatically
  • Disabled: Changes only affect the current driver, allowing independent delay values
  • Activating Sync: If Sync is currently disabled and you enable it, an automatic delay detection is triggered to ensure all drivers have coherent delay values

When to use independently (Sync disabled):

  • Only when drivers were measured with significantly different microphone positions
  • Even then, prefer fixing microphone position and re-measuring rather than relying on delay compensation

Purpose and Limitations

What delay compensation is FOR:

  • Removing the time of flight of sound from the measurement (optional, depends on personal preference)
  • Correcting for different microphone positions between measurements

What delay compensation is NOT for:

  • ❌ Time-aligning drivers during crossover design (this is handled separately by the Time Delay parameter)
  • ❌ A tool for precise multi-driver coherence (proper crossover phase design is required instead)

Important: Microphone Position Corrections

Delay compensation can correct for microphone position differences, but this method has significant limitations:

⚠️ High-frequency measurement errors scale with wavelength:

  • 10 cm microphone position difference → Errors above ~3400 Hz
  • 5 cm microphone position difference → Errors above ~6900 Hz
  • Ultra-short wavelengths (high frequencies) amplify measurement uncertainties

Best practice:

  • ✅ Prefer re-measuring with fixed microphone placement rather than compensating for position differences
  • ✅ Maintain consistent microphone position across all measurements when possible
  • ✅ Delay compensation cannot replace careful measurement technique

Off-Axis Measurements:

  • The selected delay compensation applies uniformly to all off-axis measurements (cannot vary by angle)
  • This affects the relative timing between different measurement angles consistently

Measurement Notes

Section: Collapsible header (default closed) Purpose: Document measurement conditions and hardware setup

Measurement Notes Measurement Notes

Overview

The Measurement Notes field provides a space to record important information about your measurement setup, hardware configuration, environmental conditions, and any other relevant details.

Features

  • Multi-line text editor: Supports up to 1000 characters
  • Auto-save: Notes are saved with the project
  • Hint text: Helpful placeholder text suggests what information to include
  • Character counter: Live display of character count (e.g., "127/1000 characters")

What to Document

Hardware configuration:

  • Microphone model and serial number
  • Audio interface model and settings
  • Amplifier configuration
  • Cable connections and routing

Measurement conditions:

  • Date and time of measurement
  • Room conditions (temperature, humidity if relevant)
  • Microphone position and distance
  • Driver orientation and mounting

Reference information:

  • Calibration file version used
  • Sample rate and sweep settings
  • Any unusual conditions or observations
  • Version of measurements for tracking

Example Notes

Microphone: UMIK-1 (S/N: 123456) with cal file v2.3
Interface: Focusrite Scarlett 2i2 (48kHz, 512 buffer)
Distance: 1m on-axis, driver mounted in baffle
Room: Semi-anechoic (windows gated at 10ms)
Date: 2025-12-14
Notes: First measurement after driver break-in period

Best Practices

  • Be specific: Include model numbers and serial numbers when relevant
  • Date your measurements: Track when measurements were taken
  • Note calibration: Record which calibration file was used
  • Document changes: If re-measuring, note what changed
  • Reference conditions: Record anything that might affect comparisons

Exporting Impulse Responses

Impulse responses can be exported individually or in batch using two methods:

Spliced measurements: if a near-field / far-field splice is active (see Near-Field / Far-Field Splicing), the export dialog adds a Raw capture / Spliced (anechoic) choice. "Spliced" writes the blended anechoic IR (and adds a _spliced marker to the filename). "Include distortion" can be combined with either choice — it prepends the distortion tail measured at capture time to whichever main response you export (marker becomes _spliced_dist when both apply). The choice defaults to "Spliced" when the measurement being exported has a spliced version.

Individual Export (Per-Measurement)

For each measurement (horizontal and vertical angles):

  1. Click the ⬇ (Export) button next to the measurement angle
  2. Export dialog appears with format options
  3. Choose export format (WAV or TXT) and options
  4. File is saved with automatic angle suffix

File naming format:

  • Format: DriverName_v{vertical}h{horizontal}.extension
  • Examples:
    • On-axis (0°, 0°): Driver 1_v0h0.wav
    • Horizontal +30°: Driver 1_v0h30.wav
    • Vertical -15°: Driver 1_v-15h0.wav
    • Horizontal -45°: Driver 1_v0h-45.wav

Room Calibration mode (no angles):

  • Format: MeasurementName.extension
  • Example: Measurement 1.wav

Batch Export (All Measurements)

Button: ⬇ Export All (above "Measurement angle" field)

Process:

  1. Click "⬇ Export All" button
  2. Select output directory in folder picker
  3. All measurements exported simultaneously as WAV files
  4. Files use consistent v{vertical}h{horizontal} naming

Format (batch export):

  • All files exported as WAV (32-bit float, mono)
  • Sample rate matches project sample rate
  • "Include distortion" option applies to all files
  • No format selection (always WAV for batch)

Benefits:

  • Fast export of complete measurement sets
  • Consistent naming for re-import compatibility
  • Files can be re-imported via batch import with automatic angle detection
  • Compatible with external tools

Use cases:

  • Archiving complete measurement sets
  • Sharing measurements with collaborators
  • External processing (FIR Designer, Matlab, REW)
  • Backing up measurements before making changes

Export Format Options

When you click the export button, a dialog presents two format options:

WAV Format

File format:

  • Channels: Mono
  • Bit depth: 32-bit PCM float
  • Sample rate: Project sample rate

Include Distortion Metadata option:

When checked:

  • Exports full deconvolved IR plus custom 'dist' metadata chunk
  • File name automatically gets _dist.wav suffix
  • Enables THD computation when re-imported into LinFIR
  • Contains sweep parameters: start frequency, end frequency, duration

When unchecked:

  • Exports only the active (cropped/windowed) working IR
  • Standard WAV file without metadata
  • Cannot be used for THD computation upon re-import

TXT Format

File format:

  • One sample per line in scientific notation (e.g., 1.234567e-03)
  • Metadata stored as comment lines starting with #:
    • # fs=<value> - Sample rate in Hz
    • # IR data: - Marks the start of sample data
  • Compatible with external tools (e.g., Matlab, Python)
  • Can be re-imported into LinFIR

Include Distortion option:

TXT export does NOT support distortion export:

  • The "Export as TXT" button is disabled when "Include distortion" is checked
  • TXT format can only export the cropped IR (main impulse only)
  • For distortion data export, use WAV format which supports embedded metadata

THD Availability

Total Harmonic Distortion (THD) graphs are only available when:

  • IR was captured directly via LinFIR's built-in sweep, or
  • IR was imported from WAV with 'dist' metadata chunk (exported with "Include dist." option in LinFIR)

Plain WAV files without 'dist' chunk or TXT files cannot produce THD curves.


Best Practices

For Captures

  • Use proper gain staging to avoid clipping
  • Monitor levels during sweep - aim for -6 dB to -12 dB peak
  • Save captures with "Include dist." for future THD analysis

For Windowing

  • Use anechoic or quasi-anechoic measurements when possible
  • Apply windowing before designing correction filters
  • Check impulse response graphs to verify proper window placement
  • Use Adaptive Window cautiously - verify bass response is realistic

For File Management

  • Use descriptive IR names for organization
  • Export with distortion metadata if you need THD analysis later
  • Keep original unprocessed captures as backups
  • Document measurement conditions (position, distance, etc.)

Quick Reference

ActionResult
Import WAVLoad IR from WAV file (with or without 'dist' metadata)
Import FRDConvert frequency response data to impulse response
Capture SweepBuilt-in measurement with automatic THD support
Time WindowingExtract portion of IR, exclude reflections
Adaptive WindowFrequency-dependent windowing for bass preservation
Delay CompensationShift IR in time (non-destructive)
Export WAVSave IR to WAV (with optional distortion metadata)
Export TXTExport coefficients to text file