Measuring a Passive Cardioid in the Near Field

Indoors, the bass of a loudspeaker is usually measured in the near field. A microphone is placed a few millimetres from each element that radiates, its capture is scaled to the flow that element moves, and the flows are then radiated to the measuring point and added up. Above a transition band, a far-field measurement takes over, cut before the room's first reflection arrives. In two earlier articles I looked at what a near-field microphone hears of its neighbours and at how high the near field can be trusted.

A passive cardioid is a harder test. The rear wave of its cone leaves through slots in the side walls, and behind the speaker the two nearly cancel, so the rear null is the small difference between two large flows. An error of a few degrees on their relative phase is then enough to move it by several decibels. I wanted to see how LinFIR copes with that, and for this I needed a cardioid whose response is known in every direction. Only a simulation gives that, and Huygens, my loudspeaker design software, can make one.

1. The speaker

The speaker is a three-way cardioid I designed in Huygens, and this study is about its woofer way. A 12-inch woofer (SB Audience NERO-12MWN700D) sits in a 45-litre box, and its back wave leaves through six slots, three on each side wall. Each slot is 40 × 266 mm and damped with melamine foam. Above the woofer, the midrange and the tweeter are mounted in two waveguides merged into one.

Beside the model, the figure shows four of Huygens' views of the whole speaker. The upper two are at 147 Hz, in the woofer's band, and show the level on its surface and the pressure around it in the horizontal plane at one instant. Below them are its three ways on the axis and its horizontal polar map. In these views Huygens models the air inside the cabinet by finite elements. For this study I used lumped elements instead, and with them the rear null comes out deeper, about 20 dB below the axis at 147 Hz against about 10 dB on the polar map. If anything, that makes the test harder, since the same error in phase moves a deeper null further.

The cabinet seen from above, front up: the cone on the front, three slots on each side wall, and the near-field microphones (dots). LinFIR's angles: +90° is the cabinet's left seen from the front

For the study I also removed the midrange and the tweeter and closed their holes. Huygens solves the driver's electrical and mechanical network together with the boundary elements of the cabinet, so the pressures a few millimetres from each element and the far field in every direction all come from that one solution, with no room around the speaker.

The simulated woofer at 1 m in four directions (left), and its rear rejection, the response at 0° over the one at 180°, at 1 m and 2 m (right)

The rear rejection, the response on the axis over the one behind the speaker, stays above 10 dB at 1 m from 73 Hz to 1 kHz and peaks at 22.0 dB at 180 Hz, though it is only 7.4 dB at 50 Hz. At 2 m the peak is nearly as high, 21.7 dB, but it sits lower, at 127 Hz.

2. The measurements

I took the measurements that LinFIR's splicing wizard asks for. The cone is captured 5 mm in front of its dust cap, which lies 35 mm behind its rim, and each slot 5 mm from the side wall, in the middle of its mouth. The far field is taken at 1 m and 2 m from the centre of the woofer, every 5° in the horizontal and vertical planes, which makes 145 directions in all. All the captures share one time base, as they would if they had been measured with a loopback.

Left: the seven near-field captures at 5 mm (the slots of one side, the other side is the same) beside the far field on the axis at 1 m. Right: the far field at 0° and 180°, gated 5 ms after the direct sound (dashed), over the raw simulated response (wide). The transition band is shaded

At 5 mm the cone reads 116 dB at 100 Hz for 2.83 V, which is 28 dB more than the far field on the axis at 1 m, and each slot reads about 10 dB less than the cone. A room's reflections would stay far below these levels.

The simulation has no room, so I gave LinFIR only what a room would let through. Its far-field window stops 5 ms after the direct sound, as if the first reflection arrived then, and with a window that short the far field cannot be trusted in the bass. On the axis it reads 3.3 dB too high at 30 Hz and 6.4 dB too high at 20 Hz, while behind the speaker it reads 2.4 dB too low at 150 Hz, which deepens the null. So LinFIR takes it as valid from 220 Hz and only uses it above a transition band from 250 to 500 Hz. Below that band, the response comes from the near-field captures alone.

The raw curves that I compare the splice with are the simulated far field itself, something a real measurement could only give in an anechoic room.

3. The splice

I entered the cabinet, the cone and the six slots in LinFIR through the commands of its AI assistant, which fill in the wizard just as a user would, and turned the boundary elements on. LinFIR then

The level is matched in the bass, after the prediction has gone through the same window as the far field. As for the near-field time offset, which places the near-field captures in the time base of the far-field measurement, I let it follow its matched value. It came out at 2.918 ms, against a time of flight of 2.916 ms to the microphone at 1 m. Splicing all 145 measurements took 11 seconds.

4. The result

Spliced by LinFIR 1.6.1 (thin) over the raw simulated response (wide) at 1 m in four directions, and their difference

At 1 m the spliced response stays within 0.20 dB RMS of the raw simulated one from 30 to 250 Hz over the 145 directions, and within 0.62 dB at worst. Even behind the speaker, where the cone and the slots cancel, it stays within 0.46 dB, and the phase within 1.1° RMS. At 2 m the error is a little larger, 0.30 dB RMS and 0.93 dB behind the speaker.

The rear rejection at 1 m and 2 m: raw simulated (wide), from the gated far field alone (dashed), and spliced by LinFIR 1.6.0 and 1.6.1

At 1 m the spliced rear rejection peaks at 22.2 dB at 177 Hz, and the simulated one at 22.0 dB at 180 Hz. The gated far field alone would have put that peak at 24.5 dB, and it also reads 3.3 dB too high on the axis at 30 Hz.

Spliced over raw in every direction at 1 m, in dB, with the transition band between the dotted lines

In every direction, as the map shows, the error stays within 0.62 dB from 30 to 250 Hz and within 0.32 dB across the transition band. It reaches 1.3 dB below 30 Hz, but there the level of the woofer itself has fallen by 30 dB. Above the band, the spliced response is simply the gated far field.

5. What it took

It did not work this well straight away. The first run of this comparison, with LinFIR 1.6.0, put the rear null 3.6 dB too deep, at 25.6 dB instead of 22.0, which was worse than the gated far field alone, and the error over all directions was 0.66 dB RMS. Two ways of reading the captures were behind it, and LinFIR 1.6.1 changes both.

The near field lags the flow. For a piston of radius \(a\) in a baffle, the pressure on its axis at a distance \(d\) lags the flow it moves by a pure delay,

$$\tau = \frac{d + \sqrt{d^2 + a^2}}{2c} ,$$

which comes to 0.20 ms for the 12-inch cone at 5 mm and to 0.12 ms in the middle of a slot. LinFIR used to leave each capture with its lag and let the near-field time offset take up a single lag for all the elements. That is right when the elements are all the same size, but here they are not, and the slots' flows came out about 50 µs early against the cone's. This is only 3° at 150 Hz, yet an error of that size is enough to move the null by 3.6 dB. LinFIR 1.6.1 now advances each element by its own lag. A cone whose cap lies deep also lags less than a flat piston, in the same ratio as it reads louder. I fitted that on boundary element solutions of 19 cones, and for this one the ratio is 0.83.

The phase of the slots' flow against the cone's, as LinFIR reads it from the captures, minus the true one, at 1 m from 20 to 250 Hz

A cabinet is not an infinite baffle. Keele's factor is the near field of a piston in an infinite baffle, but on this cabinet the 12-inch cone's near field reads 0.8 dB below it in the bass, where the box radiates into the whole space, and 0.7 dB above it around 600 Hz. In the bass its lag is also half the baffle's. When the boundary elements are on, LinFIR 1.6.1 uses them to solve the flow behind each capture, then brings the capture to what a piston in a baffle would read for that flow. The same error also affects a single woofer in a closed box, whose predicted baffle step could come out up to 1.5 dB too high.

The time offset changed as well. It used to stay at 0 until you set it, and the wizard's Match phase read the phase at a single frequency, which can land a whole period away. It now follows a matched value found in two steps: the prediction is first placed where it best matches the gated far field, and then turned so that the two phases cross in the middle of the transition band. The wizard's sixth step can also pass the prediction through the far-field window, so you can check whether its phase follows the far field's in the bass.

6. On a real cardioid

If you measure a real cardioid, capture its slots one by one. Taking each group of three slots as one rectangle, captured at its middle slot, doubles the error at 5 mm (0.39 dB) and brings it to 0.94 dB at 5 cm, whereas each slot captured on its own does as well at 5 cm as at 5 mm (0.19 dB).

It also pays to describe the speaker exactly as it is. In one trial at 2 m I gave the cone a 20 mm cap instead of 35, put the reference point 35 cm too high and described each group as 120 mm wide instead of 180, captured at its back slot. The error was 2.7 dB RMS, and it came down to 0.7 dB once those entries were put right.

7. What this test leaves out

The simulation has no room and no noise, and its microphones stand exactly where LinFIR places them. Still, it does not copy LinFIR's model. The slots lean back by 10° while LinFIR takes them as straight, and the cabinet has 1 cm chamfers and roundovers that LinFIR's box does not have. In the simulation, though, each slot radiates as a flat piston flush with the wall, all six with the same velocity, and the mouth of a real slot only approaches that.

8. Conclusion

From near-field captures at 5 mm and a far field gated 5 ms after the direct sound, LinFIR 1.6.1 recovers the response of this passive cardioid in 145 directions within 0.2 dB RMS from 30 to 250 Hz, and its rear rejection within 0.2 dB at the peak. The rear null made the case demanding, because it rests on the phase between the cone and the slots, and getting it right took two changes in the way LinFIR reads the captures.

If you measure a cardioid with LinFIR, or have one measured both in the near field and outdoors, please write to me through the contact page.

How the simulation was made

Huygens 0.1.19 solved the woofer way with the driver's network coupled to the boundary elements of the cabinet (Burton–Miller formulation) and the interior as a lumped model. The mesh had triangles with 10 mm edges, and the solution ran from 10 Hz to 3 kHz at 48 frequencies per octave. The pressures were read where LinFIR's microphones stand, 3 to 100 mm in front of the cone and of each slot, and on circles of 1 m and 2 m around the woofer's centre, every 5° in both planes. Every impulse response then went through the same filters, a second-order high-pass at 4 Hz and an eighth-order low-pass at 2.5 kHz since the solution stops at 3 kHz, and through the same 1 ms latency. LinFIR spliced them with the boundary elements on, its far-field window ending 5 ms after the direct sound, the transition from 250 to 500 Hz and the level matched from 12 to 35 Hz.

References

  1. Keele, D. B., Jr., "Low-Frequency Loudspeaker Assessment by Nearfield Sound-Pressure Measurement", Journal of the Audio Engineering Society, 22(3), 154–162, 1974. The near-field method and its scaling.

  2. Struck, C. J. and Temme, S. F., "Simulated Free Field Measurements", Journal of the Audio Engineering Society, 42(6), 467–482, 1994. Near-field and gated far-field measurements spliced together.

  3. Demion, A., "What a Near-Field Microphone Really Hears", DEM Audio blog, 2026, /blog/near-field-cross-talk/. The separation of the captures.

  4. Demion, A., "How High Can a Near-Field Measurement Go?", DEM Audio blog, 2026, /blog/near-field-ceiling/. The ceiling of the near field and a cone's level.

  5. Demion, A., "A Boundary Element Solver on Apple's GPU, Checked Against AKABAK", DEM Audio blog, 2026, /blog/bem-on-the-gpu/. Huygens' solver against exact solutions and AKABAK 3.

Questions or corrections?

A correction is more useful than a compliment. Write to me.